Corrosion is a key issue in extreme marine, mining, industrial and mobile applications, as well as many other markets, which can cause direct and indirect economic loss. In this regard, higher requirements are needed for the corrosion resistance of hydraulic joint fittings.
After more than 20 years of continuous exploration, trial, and development, the continuous iteration of mechanical production equipment update, DME greatly improved the standard corrosion resistance of hydraulic fittings. According to SAE standardized salt spray test, there will be no red rust in harsh environment. Excellent corrosion resistance can provide a safe and effective linkage solution for your hydraulic system.
Cladding material parsing
1. The surface is chromate passivated. The resulting treatment should be completely free of hexavalent chromium.
2. The thickness of the sealant is about 2 um.
3. Total thickness is 8-12 um.
4. Smooth surface, fine grain, adhesion, no blisters, pits, or nodules
要素Element |
重量百分比 Weight Percentage |
镍Nickel |
10-15 |
DME锌镍层厚度检测报告The Test Report of Ni-Zn Layer Thickness |
||||||
表单编号Form Number |
DMJX-JL-255 |
日期Date |
2022.03.18 |
|||
产品名称Product Name |
液压件 Hydraulic Adaptor
|
项目名称Project Name |
锌镍层厚度检测 Ni-Zn Layer Thickness |
|||
产品型号Product Model |
DABPM107M-2020-ZNNI |
项目编号Project Number |
20220318C107 |
|||
委托单位Entrusting Party |
DME |
项目标准Project Standard |
ASTMB117
|
|||
外观检查Appearance Inspection |
划伤 Scratch |
异物Foreign Matter |
色泽Lustre |
|||
N/A |
N/A |
OK |
||||
检查数量Sample Number |
① |
② |
③ |
|||
检测值:Test Value |
|
|
|
|||
平均值:Mean Value |
10.23 |
单位:um |
||||
检测结论Test Conclusion |
合 格 |
|||||
制表Lister |
张琪Zhang Qi |
检验员Inspector |
张琪Zhang Qi |
审核Auditor |
刘勇Liu Yong |
In order to demonstrate the corrosion resistance of the DME joint, the DME DABPM107M-2020-Ni-Zn hydraulic pipe joint was selected and the salt spray test was performed under ASTM B117 and ISO 9227 standard conditions. And the change time was recorded as well.
DME's Ni-Zn electroplating for hose fittings has been proven to withstand 1000 hours of corrosion resistance, with no red rust appearing far beyond of SAE standards, which can effectively resist harsh and complex corrosion environments.
Copyright © 1993~2024 DME INDUSTRIES CO.,LTD.